PVC Schedule 40 Pipe

PURCHASE FROM OUR STORE

1 1/2

1 1/2" PVC Schedule 40 Pipe x 10' (Plain End)

  • SKU: 40P015PE10
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 330 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 1.90"
    • Minimum Wall Thickness: .145"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

1 1/2

1 1/2" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P015BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 330 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 1.90"
    • Minimum Wall Thickness: .145"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

1 1/4

1 1/4" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P012BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 370 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 1.66"
    • Minimum Wall Thickness: .14"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

1

1" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P010BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 450 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 1.315"
    • Minimum Wall Thickness: .133"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

1/2

1/2" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P005BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 pipe is used in outdoor water lines, swimming pools, irrigation lines, underground sprinkler systems, and other outdoor applications.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 600 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 0.84"
    • Minimum Wall Thickness: .109"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

10

10" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P10020BE
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 140 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 10.75"
    • Minimum Wall Thickness: .365"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

12

12" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P120BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 12.75"
    • Minimum Wall Thickness: .406"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

14

14" PVC Schedule 40 Pipe x 20' (PE)

  • SKU: 40P140PE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 14.00"
    • Minimum Wall Thickness: .437"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

16

16" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P160BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 16.00"
    • Minimum Wall Thickness: .50"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

18

18" PVC Schedule 40 Pipe x 20' (PE)

  • SKU: 40P180PE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 18.00"
    • Minimum Wall Thickness: .562"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

2 1/2

2 1/2" PVC Schedule 40 Pipe x 20' (BE)

  • SKU: 40P025BE20
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 300 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 2.875"
    • Minimum Wall Thickness: .203"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.

2

2" PVC Schedule 40 Pipe x 10' (Plain End)

  • SKU: 40P020PE10
  • Brand:

  • Product Description:

    PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.

    • Typically used in industrial applications.
    • Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
    • Pressure Rating Per Sq. Inch @ 73.4_ F: 280 psi
    • Maximum PVC Service Temperature: 140F
    • Pressure ratings decrease as temperature increase.
    • Outside Diameter: 2.375"
    • Minimum Wall Thickness: .154"
    • Color: White
    • Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
    • DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.