PVC Backwater Valves are designed to prevent fluids from re-entering drainage systems, should backflow occur. Unidirectional flow through the valve is created by a flap that freely opens during outflow, and is trapped closed if backflow occurs.
PVC Backwater Valves are designed to help prevent fluids from re-entering drainage systems, should backflow occur. Unidirectional flow through the valve is created by a flap that freely opens during outflow, and is trapped closed if backflow occurs.
Both ends fit over Schedule 40 DWV pipe
8" PVC DWV Fabricated Backwater Valve (S x S)
SKU: 875P
Brand:
Product Description:
PVC Backwater Valves are designed to prevent fluids from re-entering drainage systems, should backflow occur. Unidirectional flow through the valve is created by a flap that freely opens during outflow, and is trapped closed if backflow occurs.
Backwater Valves are designed to prevent backflow in numerous applications where easy service access for maintenance and cleaning is needed. Excellent for use in sanitary or storm sewer drainage systems to prevent waste back up due to inadequate drainage, for balancing multi-level ponds, aquaculture features or storage tank systems, and many other applications. Spears® Backwater Valve has been engineered for improved function and easier service, especially in buried service with use of optional Service-Access Extension Kit.
All PVC Construction with EPDM Flapper Seal
Threaded Top Plug for Convenient Service
Simple Snap-In Internal Flapper Assembly for Easy Replacement
Optional Factory Assembled Service-Access Extension Kits - External Housing with Internal Extension for Convenient Removal, Inspection or Replacement
Optional Extension Components Kits for Assembly with User-Supplied Pipe
Available in Sizes 2", 3", 4" and 6" with Socket Ends
Direct Connection to ASTM D 2665 PVC DWV or other IPS size pipe. Spears® IPS x Sewer Adapters Available for Connection to ASTM 3034 Sewer
Conforms to ASME/ANSI A112.14.1 for Backwater Valves
Pressure Rated to 43 psi (100 feet of head) @ 73°F
Backwater Valves are designed to prevent backflow in numerous applications where easy service access for maintenance and cleaning is needed. Excellent for use in sanitary or storm sewer drainage systems to prevent waste back up due to inadequate drainage, for balancing multi-level ponds, aquaculture features or storage tank systems, and many other applications. Spears® Backwater Valve has been engineered for improved function and easier service, especially in buried service with use of optional Service-Access Extension Kit.
All PVC Construction with EPDM Flapper Seal
Threaded Top Plug for Convenient Service
Simple Snap-In Internal Flapper Assembly for Easy Replacement
Optional Factory Assembled Service-Access Extension Kits - External Housing with Internal Extension for Convenient Removal, Inspection or Replacement
Optional Extension Components Kits for Assembly with User-Supplied Pipe
Available in Sizes 2", 3", 4" and 6" with Socket Ends
Direct Connection to ASTM D 2665 PVC DWV or other IPS size pipe. Spears® IPS x Sewer Adapters Available for Connection to ASTM 3034 Sewer
Conforms to ASME/ANSI A112.14.1 for Backwater Valves
Pressure Rated to 43 psi (100 feet of head) @ 73°F
A Backwater Valve is designed to function as a check valve in a drainage pipe to prevent flowing liquid, such as sewage, from reversing its direction. There are other applications for Backwater Valves, such as multi-level pond balancing for Aquascape applications or for storage tank balancing for industrial and agricultural applications. Backwater Valves should not be confused with Backflow Preventers which are used in potable water supply systems.
Backwater valves are most important if you are on a public sewer system, especially if you are the lowest home on the line where you could have everyone’s sewage above you flow into your home if there is a stoppage in the mainline after your connection. Some jurisdictions require Backwater Valves on new construction.
Replaceable internal flapper assembly
Extension Kit Adapter components allow easy construction of a valve extension with user supplied pipe cut to desired length
Direct Valve Connection to ASTM D 2665 PVC DWV or other IPS size pipe. Spears® IPS DWV x Sewer & Drain Adapter Bushings are available for connection to ASTM D 3034 & ASTM D 2729 Sewer pipe
Standard Valve Adapters Pressure Rated to 50 psi (115 feet of head) @ 73°F (23°C) - Optional 100 psi Adapter (232 feet of head) available
Conforms to ASME/ANSI A112.14.1 for Backwater Valves
Backwater Valves are designed to prevent backflow in numerous applications where easy service access for maintenance and cleaning is needed. Excellent for use in sanitary or storm sewer drainage systems to prevent waste back up due to inadequate drainage, for balancing multi-level ponds, aquaculture features or storage tank systems, and many other applications. Spears® Backwater Valve has been engineered for improved function and easier service, especially in buried service with use of optional Service-Access Extension Kit.
All PVC Construction with EPDM Flapper Seal
Threaded Top Plug for Convenient Service
Simple Snap-In Internal Flapper Assembly for Easy Replacement
Optional Factory Assembled Service-Access Extension Kits - External Housing with Internal Extension for Convenient Removal, Inspection or Replacement
Optional Extension Components Kits for Assembly with User-Supplied Pipe
Available in Sizes 2", 3", 4" and 6" with Socket Ends
Direct Connection to ASTM D 2665 PVC DWV or other IPS size pipe. Spears® IPS x Sewer Adapters Available for Connection to ASTM 3034 Sewer
Conforms to ASME/ANSI A112.14.1 for Backwater Valves
Pressure Rated to 43 psi (100 feet of head) @ 73°F
Convert from Schedule 40 to SDR35 with bushing Part# P118-040
A Backwater Valve is designed to function as a check valve in a drainage pipe to prevent flowing liquid, such as sewage, from reversing its direction. There are other applications for Backwater Valves, such as multi-level pond balancing for Aquascape applications or for storage tank balancing for industrial and agricultural applications. Backwater Valves should not be confused with Backflow Preventers which are used in potable water supply systems.
Backwater valves are most important if you are on a public sewer system, especially if you are the lowest home on the line where you could have everyone’s sewage above you flow into your home if there is a stoppage in the mainline after your connection. Some jurisdictions require Backwater Valves on new construction.
Replaceable internal flapper assembly
Extension Kit Adapter components allow easy construction of a valve extension with user supplied pipe cut to desired length
Direct Valve Connection to ASTM D 2665 PVC DWV or other IPS size pipe. Spears® IPS DWV x Sewer & Drain Adapter Bushings are available for connection to ASTM D 3034 & ASTM D 2729 Sewer pipe
Standard Valve Adapters Pressure Rated to 50 psi (115 feet of head) @ 73°F (23°C) - Optional 100 psi Adapter (232 feet of head) available
Conforms to ASME/ANSI A112.14.1 for Backwater Valves
Available in Sizes 3", 4" and 6" with Socket Ends
Convert from Schedule 40 to SDR35 with bushing Part# P118-040