Septronics 120V Exterior Pump Controls and Alarms _ Jiffy Junction
SKU: JJ1
Brand:
Product Description:
Control a pump and monitor the liquid level(s) of the tank in one exterior based unit. Pump is connected into the corded recptacle located in a watertight box. This exterior based unit has a removable terminal board for all the wire connections. The light will remain illuminated unitil the liquid returns to an appropriate level.
Horn Silence and Alarm Test
Gas Tight Cord Seals for Corrosion Protection
Removable Terminal Board for Easy Hook-up
Watertight Junction Box for Wire Splices
Corded Receptacle for Hook-up Mobility
Control Switch (included) activates Audiovisual Alarms
Pipe Nipple & Locknuts included to fit directly on Riser
Septronics 120V Mini Jiffy Junction Box - No Alarm
SKU: MJJ1X
Brand:
Product Description:
Low profile 120V alarm/pump control junction box with a molded pipe nipple. No Interior Alarm and Control Switch are included in this unit.
Septronics 230V Exterior Pump Controls and Alarms - Mini Jiffy
SKU: PMJ230
Brand:
Product Description:
Control a pump and monitor the liquid level(s) of the tank. Pump is connected into the corded receptacle located in a watertight box. This exterior portion of the unit has a removable terminal board for all the wire connections.
Liberty Grinder Pump Receptacle
Horn Silence and Alarm Test
Gas Tight Cord Seals for Corrosion Protection
Removable Terminal Board for Easy Hook-up
Watertight Junction Box for Wire Splices
Corded Receptacle for Hook-up Mobility
Control Switch (included) activates Audiovisual Alarms
Pipe Nipple & Locknuts included to fit directly on Riser
Septronics 230V Exterior Pump Controls and Alarms _ Jiffy Junction
SKU: JJ230
Brand:
Product Description:
Control a pump and monitor the liquid level(s) of the tank in one exterior based unit. Pump is connected into the corded recptacle located in a watertight box. This exterior based unit has a removable terminal board for all the wire connections. The light will remain illuminated unitil the liquid returns to an appropriate level.
Liberty Grinder Pump Receptacle
Horn Silence and Alarm Test
Gas Tight Cord Seals for Corrosion Protection
Removable Terminal Board for Easy Hook-up
Watertight Junction Box for Wire Splices
Corded Receptacle for Hook-up Mobility
Control Switch (included) activates Audiovisual Alarms
Pipe Nipple & Locknuts included to fit directly on Riser
Septronics 27" Polyethylene Pedestal ONLY
SKU: 3011
Brand:
Product Description:
High Impact Polyethylene Pedestal for outdoor use with UV inhibitors.
27? tall pedestal includes removable front access door for easy routing of wires.
Top and bottom of pedestal are open for easy access to run wires for control panel and for mounting.
Back plate bolt pattern designed to fit standard control panels.
Easy to install junction box provides convenient wiring connection for use with one single phase pump in effluent and sewage chambers.
This junction box provides a convenient location to connect all wiring required for a typical pumping station installation. The junction box employs a receptacle to accept a 120 VAC piggy-back plug and a pump plug.
The JB Plugger?also features an easy-to-use terminal strip which can be used for connecting an alarm system in the junction box.
The JB Plugger?package ensures a liquid-tight seal and strain relief for the cable entering the junction box from the pumping station.
NEMA 4X enclosure with hinged door.
Separate alarm and pump control circuit.
Receptacle for pump and pump switch (120V).
Tank Alert AB alarm system provides high or low level alarm (optional-not included).
Pump float provides pump control (optional-not included).
Control fl oat provides alarm activation (optional-not included).
Riser extension coupling and washers.
Custom engineered liquid-tight cable seal.
Strain relief for pump and float cords provided by cord seal.
Electrical conduit hub.
Terminal strip for use with alarm system.
Entire control system (panel and switches) is UL and cUL Listed to meet and/or exceed industry safety standards.
SJE Rhombus 4X-01H Sensor Floatå High Level 1008023
SKU: 1008023
Brand:
Product Description:
Easy-to-install liquid level alarm system which has a NEMA 4X enclosure for indoor or outdoor use.
This alarm system monitors liquid levels in lift pump chambers, sump pump basins, holding tanks, sewage, agricultural, and other water applications.
The Tank Alertå 4X alarm system can serve as a high or low level alarm depending on the float switch model used.
The stainless steel alarm horn sounds and red beacon illuminates when a potentially threatening liquid level condition occurs. The horn can be silenced, but the alarm beacon remains on until the condition is remedied. Once the condition is cleared the alarm will automatically reset.
NEMA 4X enclosure rated for indoor or outdoor use.
Automatic alarm reset and alarm test/normal/silence switch.
Alarm horn sounds at 88 decibels at 10feet (3 meters)
Alarm system (when installed on separate circuit) operates even if the pump circuit fails.
Complete package includes standard SJE SignalMasterå control switch with 15 feet (4.57 meters) of cable (other lengths available) and mounting clamp.
Dual UL safety certification for the United Sates and Canada
Mercury activated, wide-angle switch designed for direct control of pumps.
This mercury activated, wide-angle pump switch provides automatic control of pumps in nonpotable water and sewage applications. It is well-suited for confined applications requiring an accurate pumping range. It is not sensitive to rotation or turbulence. This switch is voltage sensitive - use with correct voltage.
The Double Float pump switch consists of two floats and a splice tube. Each float contains a heavy-duty mercury switch. The splice tube contains a holding relay which enables the floats to function in series.
The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float pump switch to operate relay control panels for larger pump applications.
Controls pumps up to 1 HP at 120 VAC.
Adjustable pumping range of 1.75 to 48 inches (4.45 to 122 cm) with increased pumping range up to 6 feet (1.8 meters) available.
Includes standard mounting clamp and boxed packaging.
UL Recognized for use in non-potable water and sewage.
Mercury activated, wide-angle switch designed for direct control of pumps.
This mercury activated, wide-angle pump switch provides automatic control of pumps in nonpotable water and sewage applications. It is well-suited for confined applications requiring an accurate pumping range. It is not sensitive to rotation or turbulence. This switch is voltage sensitive - use with correct voltage.
The Double Float pump switch consists of two floats and a splice tube. Each float contains a heavy-duty mercury switch. The splice tube contains a holding relay which enables the floats to function in series.
The holding relay eliminates pump chatter in turbulent conditions allowing the Double Float pump switch to operate relay control panels for larger pump applications.
Controls pumps up to 1 HP at 230 VAC.
Adjustable pumping range of 1.75 to 48 inches (4.45 to 122 cm) with increased pumping range up to 6 feet (1.8 meters) available.
Includes standard mounting clamp and boxed packaging.
UL Recognized for use in non-potable water and sewage.
SJE Rhombus Junior, Super, Single, Pump Switch 1001817
SKU: 1001817
Brand:
Product Description:
Mercury activated, wide-angle switch designed for direct control of pumps.
This mercury activated, wide-angle pump switch provides automatic control of smaller pumps in non-potable water and sewage applications.
Although this switch is not sensitive to rotation, it is affected by turbulence and should be mounted in a non-turbulent location.
The Junior Super Single pump switch is not recommended for use with motor contactors or relays because the motor contactor or relay may experience chattering. A Super Single or Double Float pump switch would operate more efficiently in these installations.
Controls pumps up to 1/2 HP at 120 VAC.
Adjustable pumping range of 6.5 to 19 inches (16.5 to 48 cm).
Includes standard mounting clamp and boxed packaging.
UL Recognized for use in non-potable water and sewage.