PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 330 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 1.90"
Minimum Wall Thickness: .145"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
1 1/2" PVC Schedule 40 Pipe x 20' (BE)
SKU: 40P015BE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 330 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 1.90"
Minimum Wall Thickness: .145"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
Used for Drain Waste & Vent and pressure applications.
Outside Diameter: 1.66"
Meets ASTM D2665 and ASTM D1785
Dual Rated
Drain Waste & Vent (DWV)
Pressure Rating: 370 PSI
Both ends plain end
10" PVC Schedule 40 Pipe x 20' (BE)
SKU: 40P10020BE
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 140 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 10.75"
Minimum Wall Thickness: .365"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
12" PVC Schedule 40 Pipe x 20' (BE)
SKU: 40P120BE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 12.75"
Minimum Wall Thickness: .406"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
14" PVC Schedule 40 Pipe x 20' (PE)
SKU: 40P140PE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 14.00"
Minimum Wall Thickness: .437"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
16" PVC Schedule 40 Pipe x 20' (BE)
SKU: 40P160BE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 16.00"
Minimum Wall Thickness: .50"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
18" PVC Schedule 40 Pipe x 20' (PE)
SKU: 40P180PE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 130 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 18.00"
Minimum Wall Thickness: .562"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
2 1/2" PVC Schedule 40 Pipe x 20' (BE)
SKU: 40P025BE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 300 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 2.875"
Minimum Wall Thickness: .203"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
2" PVC Schedule 40 Pipe x 10' (Plain End)
SKU: 40P020PE10
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 280 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 2.375"
Minimum Wall Thickness: .154"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.
2" PVC Schedule 40 Pipe x 20' (BE)
SKU: 40P020BE20
Brand:
Product Description:
PVC Schedule 40 Pipe is for pressure applications, and has a thicker wall than than Schedule 40 pipe. PVC Schedule 40 is highly durable, with high tensile and impact strength.
Typically used in industrial applications.
Meets or Exceeds Following Standards: ASTM D1785 NSF approval for drinking water use.
Pressure Rating Per Sq. Inch @ 73.4_ F: 280 psi
Maximum PVC Service Temperature: 140F
Pressure ratings decrease as temperature increase.
Outside Diameter: 2.375"
Minimum Wall Thickness: .154"
Color: White
Installation requires cement and primer. Choose the proper cement designed for the diameter and type of pipe and fittings you are installing.
DO NOT USE PLASTIC PIPE AND FITTINGS FOR COMPRESSED AIR.