ATL by Infiltrator is a passive advanced treatment leachfield system designed as an environmentally friendly alternative to traditional stone and pipe drainfields. The ATL system is a sand-lined treatment and dispersal leachfield system consisting of 6 components.
How It Works
Upon entering the system, septic tank effluent progresses through each component listed below.
4" diameter pipe
Large-diameter synthetic aggregate
Fine geotextile
Small-diameter synthetic aggregate
Coarse geotextile
6" thick system sand
Benefits:
Produces Class 1 (EPA Secondary) Treated Effluent
A Passive Advanced Treatment Leachfield _ No Moving Parts or Power Required
Modules are Quick and Easy to Install
Shallow System Maximizes Site Suitability and Reduces Amount of Sand Fill Requirements
ATL by Infiltrator is a passive advanced treatment leachfield system designed as an environmentally friendly alternative to traditional stone and pipe drainfields. The ATL system is a sand-lined treatment and dispersal leachfield system consisting of 6 components.
How It Works
Upon entering the system, septic tank effluent progresses through each component listed below.
4" diameter pipe
Large-diameter synthetic aggregate
Fine geotextile
Small-diameter synthetic aggregate
Coarse geotextile
6" thick system sand
Benefits:
Produces Class 1 (EPA Secondary) Treated Effluent
A Passive Advanced Treatment Leachfield _ No Moving Parts or Power Required
Modules are Quick and Easy to Install
Shallow System Maximizes Site Suitability and Reduces Amount of Sand Fill Requirements
This end cap features pipe cutouts on the right and left column designed to accommodate inspection ports, clean outs, or inlet pipes on either side of the end cap. These pipe locations allow easy access for maintenance and alignment when running pressure pipe through the chamber. The Quick4 Plus™ All-in-One 8 Endcap may be used at either end of a chamber row or can be installed mid-trench for an inspection port, cleanout or inlet/outlet pipe. The mid-trench connection feature allows construction of chamber rows with center feed inletting for easy installation of serial distribution systems. Pipe connection options allow for side, end or top inletting.
Benefits:
May be used at the end of chamber row for an inlet/outlet or can be installed mid-trench
Mid-trench connection feature allows center feed inletting of chamber rows
Center-feed connection allows for easy installation of serial distribution systems
Variable pipe connection options allow for side, end or top inletting
Piping drill points are set for gravity or pressure pipe
The Quick4 Plus™ Standard Low Profile (LP) offers maximum strength through its four center structural columns. This chamber can be installed in a 36" wide trench. It is shorter in height than Infiltrator’s other Standard model chambers, allowing for shallow installation. Like the original line of Quick4® chambers, it offers advanced contouring capability with its Contour Swivel Connection™, which permits turns up to 10°, right or left.
Benefits:
Low profile design makes this chamber ideal for shallow applications
Reduces imported fill needed for cap and fill systems
Four center structural columns offer superior strength
Advanced contouring connections
Latching mechanism allows for quick installation
Four-foot chamber lengths are easy to handle and install
Supports wheel loads of 16,000 lbs/axle with 12" of cover
Specifications:
Size 34"W x 53"L x 8"H (864 mm x 1346 mm x 203 mm)
For use with the Quick4 Plus™ Low Profile chambers, the Quick4 Plus endcap offers a simple, flat design and allows installation of a pipe from the end of the chamber rows. Piping drill points are set for gravtiy or pressure points.
Benefits:
Simple, flat design
Allows installation of a pipe from the end only
Piping drill points are set for gravity or pressure pipe
The Quick4 Plus™ All-In-One 12 Endcap may be used at either end of the chamber row for an inlet/outlet or can be installed mid-trench. The mid-trench connection feature allows construction of chamber rows with a center-feed, as an alternative to inletting at the ends of chamber rows. Center-feed connections allow for easy installation of serial distribution systems. Pipe connection options include sides, ends or top.
Benefits:
May be used at the end of chamber row for an inlet/outlet or can be installed mid-trench
Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows
Center-feed connection allows for easy installation of serial distribution systems
Pipe connection options include sides, ends or top
Specifications:
Size 33"W x 20.5"L x 13"H (838 mm x 520 mm x 330 mm)
The Quick4 Plus™ Standard chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36" wide trench. Like the original line of Quick4® chambers, it offers advanced contouring capability with its Contour Swivel Connection™ which permits turns up to 10°, right or left. It is also available in 4' lengths to provide optimal installation flexibility.
Benefits:
Two center structural columns offer increased stability and superior strength
Advanced contouring connections
Latching mechanism allows for quick installation
Four-foot chamber lengths are easy to handle and install
Supports wheel loads of 16,000 lbs/axle with 12" of cover
Specifications:
Size 34"W x 53"L x 12"H (864 mm x 1346 mm x 305 mm)